{"product_id":"actronair-cre-071as-urc-071as-7-1kw-cassette-split-system-single-phase","title":"Actron Air CRE-071AS\/URC-071AS 7.1kW Cassette Split System - CRE-071AS","description":"\u003ch2\u003eActron Air CRE-071AS\/URC-071AS 7.1kW Cassette Split System - CRE-071AS\u003c\/h2\u003e\n\u003cp\u003eExperience superior climate control with the Actron Air CRE-071AS\/URC-071AS 7.1kW Cassette Split System. This robust system offers 7.1kW of cooling and 7.85kW of heating power, perfect for maintaining comfort in any season. With a sleek design and premium wired controller, it seamlessly integrates into any space, providing efficient and reliable performance. Ideal for both residential and commercial applications, this system ensures year-round comfort with advanced inverter technology.\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1opfp5l\" data-start=\"27\" data-end=\"334\"\u003e\n\u003cstrong data-start=\"29\" data-end=\"72\"\u003eEfficient mid-capacity cassette system:\u003c\/strong\u003e The ActronAir CRE-071AS \/ URC-071AS is a \u003cstrong data-start=\"114\" data-end=\"160\"\u003e7.1 kW reverse-cycle cassette split system\u003c\/strong\u003e, designed for \u003cstrong data-start=\"175\" data-end=\"240\" data-is-only-node=\"\"\u003emedium-sized rooms, offices, and open-plan residential spaces\u003c\/strong\u003e, delivering balanced heating and cooling performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l9phr8\" data-start=\"336\" data-end=\"560\"\u003e\n\u003cstrong data-start=\"338\" data-end=\"367\"\u003eStrong all-season output:\u003c\/strong\u003e Provides around \u003cstrong data-start=\"384\" data-end=\"431\"\u003e7.1 kW cooling and ~7.8 kW heating capacity\u003c\/strong\u003e, making it suitable for maintaining comfort year-round in typical Australian conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1g5flls\" data-start=\"562\" data-end=\"784\"\u003e\n\u003cstrong data-start=\"564\" data-end=\"595\"\u003eEven 360° air distribution:\u003c\/strong\u003e The \u003cstrong data-start=\"600\" data-end=\"633\"\u003e4-way ceiling cassette design\u003c\/strong\u003e spreads airflow in all directions, reducing hot and cold spots and improving overall room comfort consistency. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mmtmra\" data-start=\"786\" data-end=\"1023\"\u003e\n\u003cstrong data-start=\"788\" data-end=\"821\"\u003eEfficient inverter operation:\u003c\/strong\u003e Uses a \u003cstrong data-start=\"829\" data-end=\"864\"\u003etwin-rotary inverter compressor\u003c\/strong\u003e, adjusting output dynamically to match demand, improving energy efficiency and maintaining stable indoor temperatures. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4o3vz5\" data-start=\"1025\" data-end=\"1202\"\u003e\n\u003cstrong data-start=\"1027\" data-end=\"1066\"\u003eQuiet, low-profile ceiling install:\u003c\/strong\u003e The indoor unit is \u003cstrong data-start=\"1086\" data-end=\"1120\"\u003eflush-mounted into the ceiling\u003c\/strong\u003e, keeping interiors clean and minimal while maintaining strong airflow coverage.\u003c\/li\u003e\n\u003cli data-section-id=\"1d7lhh7\" data-start=\"1204\" data-end=\"1450\"\u003e\n\u003cstrong data-start=\"1206\" data-end=\"1238\"\u003eAdvanced usability features:\u003c\/strong\u003e Includes \u003cstrong data-start=\"1248\" data-end=\"1347\"\u003eindependent louvre control, adjustable fan speeds, self-diagnostics, and drain pump integration\u003c\/strong\u003e, improving installation flexibility and long-term reliability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xxzyew\" data-start=\"1452\" data-end=\"1669\"\u003e\n\u003cstrong data-start=\"1454\" data-end=\"1483\"\u003eBuilt for harsh climates:\u003c\/strong\u003e Designed to operate in \u003cstrong data-start=\"1507\" data-end=\"1585\"\u003eextreme outdoor conditions (up to ~50°C cooling and down to -25°C heating)\u003c\/strong\u003e, ensuring year-round performance stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"79\" data-end=\"305\"\u003e\u003cstrong data-start=\"79\" data-end=\"128\"\u003eQ1: What is the cooling and heating capacity?\u003c\/strong\u003e\u003cbr data-start=\"128\" data-end=\"131\"\u003eA: It delivers \u003cstrong data-start=\"146\" data-end=\"164\"\u003e7.1 kW cooling\u003c\/strong\u003e and about \u003cstrong data-start=\"175\" data-end=\"194\"\u003e7.85 kW heating\u003c\/strong\u003e, making it suitable for \u003cstrong data-start=\"219\" data-end=\"264\"\u003emedium to large rooms or open-plan spaces\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"307\" data-end=\"549\"\u003e\u003cstrong data-start=\"307\" data-end=\"343\"\u003eQ2: What type of system is this?\u003c\/strong\u003e\u003cbr data-start=\"343\" data-end=\"346\"\u003eA: It is a \u003cstrong data-start=\"357\" data-end=\"396\"\u003e4-way ceiling cassette split system\u003c\/strong\u003e, with an indoor cassette (CRE-071AS) and an outdoor inverter unit (URC-071AS) for discreet ceiling installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"551\" data-end=\"779\"\u003e\u003cstrong data-start=\"551\" data-end=\"593\"\u003eQ3: What room size is it suitable for?\u003c\/strong\u003e\u003cbr data-start=\"593\" data-end=\"596\"\u003eA: Typically suitable for \u003cstrong data-start=\"622\" data-end=\"690\"\u003elarge bedrooms, lounges, offices, or open areas around ~30–65 m²\u003c\/strong\u003e, depending on insulation and climate conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"781\" data-end=\"994\"\u003e\u003cstrong data-start=\"781\" data-end=\"812\"\u003eQ4: Is it energy efficient?\u003c\/strong\u003e\u003cbr data-start=\"812\" data-end=\"815\"\u003eA: Yes, it uses \u003cstrong data-start=\"831\" data-end=\"866\"\u003einverter twin-rotary technology\u003c\/strong\u003e with efficiency around \u003cstrong data-start=\"890\" data-end=\"923\"\u003eEER ~3.3–3.5 and COP ~3.4–3.7\u003c\/strong\u003e, helping reduce running costs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"996\" data-end=\"1187\"\u003e\u003cstrong data-start=\"996\" data-end=\"1033\"\u003eQ5: What refrigerant does it use?\u003c\/strong\u003e\u003cbr data-start=\"1033\" data-end=\"1036\"\u003eA: It uses \u003cstrong data-start=\"1047\" data-end=\"1068\"\u003eR410A refrigerant\u003c\/strong\u003e, designed for stable cooling and heating performance in Australian conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1189\" data-end=\"1416\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1235\"\u003eQ6: Does it provide good air distribution?\u003c\/strong\u003e\u003cbr data-start=\"1235\" data-end=\"1238\"\u003eA: Yes, the cassette design offers \u003cstrong data-start=\"1273\" data-end=\"1321\"\u003e360° airflow with independent louvre control\u003c\/strong\u003e, helping distribute air evenly across the entire room. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1418\" data-end=\"1621\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1455\"\u003eQ7: Is it quiet during operation?\u003c\/strong\u003e\u003cbr data-start=\"1455\" data-end=\"1458\"\u003eA: Yes, indoor noise levels typically range from \u003cstrong data-start=\"1507\" data-end=\"1544\"\u003e~40–47 dBA depending on fan speed\u003c\/strong\u003e, suitable for living and workspaces.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"5dtjiv\" data-start=\"83\" data-end=\"258\"\u003e\n\u003cstrong data-start=\"85\" data-end=\"130\"\u003eClean filters every 2–4 weeks (critical):\u003c\/strong\u003e Maintains strong airflow for 7.1 kW cooling and prevents efficiency loss or coil icing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"94sylw\" data-start=\"259\" data-end=\"376\"\u003e\n\u003cstrong data-start=\"261\" data-end=\"300\"\u003eClean indoor cassette coils yearly:\u003c\/strong\u003e Prevents dust buildup, odor issues, and reduced 360° airflow performance.\u003c\/li\u003e\n\u003cli data-section-id=\"a97owd\" data-start=\"377\" data-end=\"545\"\u003e\n\u003cstrong data-start=\"379\" data-end=\"423\"\u003eCheck condensate drain \u0026amp; pump regularly:\u003c\/strong\u003e This system includes a drain pump—keep it clear to avoid leaks or ceiling damage. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"aef2zm\" data-start=\"546\" data-end=\"715\"\u003e\n\u003cstrong data-start=\"548\" data-end=\"591\"\u003eInspect outdoor unit coil 6–12 monthly:\u003c\/strong\u003e Keeps inverter compressor efficient and prevents overheating in high ambient temps. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1u4bpab\" data-start=\"716\" data-end=\"842\"\u003e\n\u003cstrong data-start=\"718\" data-end=\"762\"\u003eMaintain 360° airflow clearance indoors:\u003c\/strong\u003e Do not block cassette discharge panels for balanced room temperature control.\u003c\/li\u003e\n\u003cli data-section-id=\"1ktvimk\" data-start=\"843\" data-end=\"965\"\u003e\n\u003cstrong data-start=\"845\" data-end=\"891\"\u003eKeep outdoor unit clear (≥30–50 cm space):\u003c\/strong\u003e Ensures proper heat exchange and stable performance in extreme weather.\u003c\/li\u003e\n\u003cli data-section-id=\"h5c9xo\" data-start=\"966\" data-end=\"1084\"\u003e\n\u003cstrong data-start=\"968\" data-end=\"1005\"\u003eCheck refrigerant lines annually:\u003c\/strong\u003e Look for insulation wear or leaks to avoid reduced cooling\/heating capacity.\u003c\/li\u003e\n\u003cli data-section-id=\"1ib21d5\" data-start=\"1085\" data-end=\"1262\"\u003e\n\u003cstrong data-start=\"1087\" data-end=\"1137\"\u003eTighten electrical connections during service:\u003c\/strong\u003e Helps prevent faults and ensures stable operation under ~17.5A full load conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zkfvyw\" data-start=\"1263\" data-end=\"1382\"\u003e\n\u003cstrong data-start=\"1265\" data-end=\"1303\"\u003eRun seasonal test (summer\/winter):\u003c\/strong\u003e Early detection of fan, sensor, or control issues before peak usage periods.\u003c\/li\u003e\n\u003cli data-section-id=\"1p6lrzf\" data-start=\"1383\" data-end=\"1503\"\u003e\n\u003cstrong data-start=\"1385\" data-end=\"1422\"\u003eAnnual professional HVAC service:\u003c\/strong\u003e Required for refrigerant handling, deep cleaning, and full system diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Actron Air","offers":[{"title":"Default Title","offer_id":45551813755071,"sku":"CRE-071AS \/ URC-071A \/ C4-p2","price":3255.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/CRE-140AS-URC-140AS_255c5faf-b048-4be8-932d-24be4e89cba5.webp?v=1777108925","url":"https:\/\/www.mybackyardzone.com\/products\/actronair-cre-071as-urc-071as-7-1kw-cassette-split-system-single-phase","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}