{"product_id":"chattanooga-optiflex-s-shoulder-cpm","title":"Chattanooga OptiFlex S Shoulder CPM - DJO-2029","description":"\u003ch2\u003eChattanooga OptiFlex S Shoulder CPM - DJO-2029\u003c\/h2\u003e\n\u003cp\u003eThe Chattanooga OptiFlex S Shoulder CPM (#2029) includes one shoulder CPM unit (which is also portable), data card, and erasable pen. Patient kits are sold separately.\u003c\/p\u003e\n\u003cp\u003eThe Chattanooga OptiFlex S Shoulder CPM is designed to address full range of motion capabilities. This include full adduction, abduction, flexion, extension, internal and external rotation, and more. The OptiFlex S is also technologically savvy, with an ease-of-use that includes a Patient Data Chip Card. This chip card can be quickly inserted into the card reader on the device, and stores individual patient data and preferences for angles, speed, and motion of the CPM device. What's more, this CPM device can also collapse and fold into a portable unit for easy transfer.\u003c\/p\u003e\n\u003cp\u003eThe unit provides patient comfort while providing anatomical motion for the shoulder for enhanced outcomes. Continuous Passive Motion (CPM) is used to help the joints of the body recover after surgery. After a surgical procedure in the shoulder, the joint must be routinely exercised to prevent the surrounding tissue from becoming stiff and forming scar tissue.\u003c\/p\u003e\n\u003ch3 style=\"display: none !important;\"\u003eFeatures\u003c\/h3\u003e\n\u003ch5\u003e Features\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to be lightweight and portable at 55 lb (25 kg).\u003c\/li\u003e\n\u003cli\u003eIncludes patient data card and erasable pen.\u003c\/li\u003e\n\u003cli\u003eEasy-to-transport with the unit€˜s folding feature.\u003c\/li\u003e\n\u003cli\u003eFully adjustable chair and patented left\/right shoulder design, with ergonomic arm rest for healthy arm.\u003c\/li\u003e\n\u003cli\u003eUser-friendly hand control for storing treatment information of a memory chip card.\u003c\/li\u003e\n\u003cli\u003eCustomizable treatment parameters that are able to be fully synchronized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"display: none !important;\"\u003eSpecifications\u003c\/h3\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eWeight\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003e55 lb (25 kg)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e34.4\" × 22.6\" × 22.8\" (87.5 × 57.5 × 58 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eTransport Size\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e14.6\" × 22.6\" × 22.8\" (37 × 57.5 × 58 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMotor Control\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eOn \/ Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003ePause Function\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0 – 30 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSpeed Control\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0 – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eTimer Range\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1 – 300 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eWarm-up Mode\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e50% of programmed ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eOn \/ Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eReverse-on-load\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1 – 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eTherapy Run Time Display\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eh : m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eAdduction \/ Abduction\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0 – 30 – 175°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInternal \/ External Rotation\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e90 – 0 – 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFlexion \/ Extension\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0 – 30 – 175°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eHorizontal Adduction \/ Abduction\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e0 – 0 – 125°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSafety Standards\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eCSA 601-1-M90, UL 2601-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eAccessories\u003c\/h5\u003e\n\u003cp\u003eThe Chattanooga OptiFlex S Shoulder CPM is commonly purchased with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e#20660: Chattanooga CPM Patient Kit - OptiFlex S.\u003c\/li\u003e\n\u003cli\u003e#20719: Chattanooga Grey Fleece Patient Kit.\u003c\/li\u003e\n\u003cli\u003e#20661: Chattanooga CPM Data Card.\u003c\/li\u003e\n\u003cli\u003e#20731: Chattanooga Instructional CD.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"display: none !important;\"\u003eLiterature\u003c\/h3\u003e\n\u003ch5\u003eLiterature\u003c\/h5\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1046\/1086\/files\/Chattanooga-CPM-and-Homecare-Catalog.pdf\" target=\"_blank\"\u003eChattanooga CPM and Homecare Catalog\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"12pfs8q\" data-start=\"28\" data-end=\"265\"\u003e\n\u003cstrong data-start=\"30\" data-end=\"81\"\u003eEngineered for advanced shoulder rehabilitation\u003c\/strong\u003e, the Chattanooga OptiFlex S delivers smooth, anatomical continuous passive motion (CPM) to support recovery following shoulder surgery or injury. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18fm3ot\" data-start=\"266\" data-end=\"449\"\u003e\n\u003cstrong data-start=\"268\" data-end=\"308\"\u003eUniversal left\/right shoulder design\u003c\/strong\u003e eliminates the need for separate units, improving efficiency and reducing equipment costs for clinics. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"c149op\" data-start=\"450\" data-end=\"659\"\u003e\n\u003cstrong data-start=\"452\" data-end=\"493\"\u003eFully programmable treatment settings\u003c\/strong\u003e allow clinicians to customize range of motion, speed, pause, and therapy duration to match individual rehabilitation protocols. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zrj0ef\" data-start=\"660\" data-end=\"814\"\u003e\n\u003cstrong data-start=\"662\" data-end=\"688\"\u003ePatient Data Chip Card\u003c\/strong\u003e stores treatment parameters for fast, consistent repeat sessions and improved workflow. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wsdjrq\" data-start=\"815\" data-end=\"1017\"\u003e\n\u003cstrong data-start=\"817\" data-end=\"849\"\u003eDesigned for patient comfort\u003c\/strong\u003e, featuring an ergonomic healthy-arm support, adjustable chair, and synchronized motors for controlled, natural shoulder movement. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w8zj3g\" data-start=\"1018\" data-end=\"1247\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"1020\" data-end=\"1059\"\u003ePortable, lightweight, and foldable\u003c\/strong\u003e, making it ideal for hospitals, orthopedic practices, rehabilitation centers, and sports medicine clinics that require flexible equipment deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the Chattanooga OptiFlex S Shoulder CPM - DJO-2029?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The Chattanooga OptiFlex S Shoulder CPM is a continuous passive motion (CPM) device designed to support shoulder rehabilitation by providing controlled, anatomical movement following surgery or injury.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What conditions is it used for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is commonly used during recovery from rotator cuff repair, shoulder replacement, capsular release, fractures, and other orthopedic shoulder procedures to help restore range of motion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What shoulder movements does it support?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The unit provides programmable flexion\/extension, adduction\/abduction, horizontal adduction\/abduction, and internal\/external rotation for comprehensive shoulder therapy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Can it be used for either shoulder?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. Its patented universal design accommodates both left and right shoulders without requiring separate models.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is the OptiFlex S easy to customize?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It features synchronized motors, an easy-to-use hand control, adjustable treatment settings, and a patient data card for storing therapy protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: What features improve patient comfort and portability?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The OptiFlex S includes an ergonomic arm support, a fully adjustable chair, a folding design for transport, and a lightweight 55 lb frame for convenient clinical use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-WEB:595715d0-29da-4a9a-a006-d1300280b27d-2\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:595715d0-29da-4a9a-a006-d1300280b27d-2\" data-turn-id-container=\"request-WEB:595715d0-29da-4a9a-a006-d1300280b27d-2\" data-testid=\"conversation-turn-6\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-3 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"e72205aa-1a74-48c3-b97e-e9156e94ceb9\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cul data-start=\"77\" data-end=\"803\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1x2jv1i\" data-start=\"77\" data-end=\"213\"\u003eClean all patient-contact surfaces with a non-abrasive, clear disinfectant after each use and keep liquids away from the control unit.\u003c\/li\u003e\n\u003cli data-section-id=\"15fvdql\" data-start=\"214\" data-end=\"319\"\u003eInspect power cords, cables, straps, and moving parts regularly; replace damaged components before use.\u003c\/li\u003e\n\u003cli data-section-id=\"1xj27i6\" data-start=\"320\" data-end=\"410\"\u003eDisconnect the unit from power before cleaning, transporting, or performing maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"165jigc\" data-start=\"411\" data-end=\"534\"\u003eKeep the device free from dust and debris, and avoid exposure to direct sunlight, excessive moisture, or harsh chemicals.\u003c\/li\u003e\n\u003cli data-section-id=\"rg39g2\" data-start=\"535\" data-end=\"627\"\u003eUse only manufacturer-approved accessories and replacement parts to ensure safe operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1fk762l\" data-start=\"628\" data-end=\"803\" data-is-last-node=\"\"\u003eHave fuse replacement and any repairs performed by qualified service personnel; inspect the unit periodically for reliable performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Chattanooga","offers":[{"title":"Default Title","offer_id":45810144444607,"sku":"DJO-2029","price":6873.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/chattanooga-optiflex-s-shoulder-cpm.jpg?v=1783135468","url":"https:\/\/www.mybackyardzone.com\/products\/chattanooga-optiflex-s-shoulder-cpm","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}