{"product_id":"es0622-ge-fanuc-6-quickpanel-view","title":"Fanuc Corporation Ge Fanuc 6\" QuickPanel View - ES0622","description":"\u003ch2\u003eFanuc Corporation Ge Fanuc 6\" QuickPanel View - ES0622\u003c\/h2\u003e\n\u003cp\u003eThe ES0622 color display is a GE Fanuc QuickPanel that comes with a 6-inch display screen. The ES0622 display features the touchscreen data entry process and a color display screen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInformation About ES0622\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe ES0622 color display is a GE Fanuc QuickPanel that comes with a 6-inch display screen. The ES0622 display features the touchscreen data entry process and a color display screen. The input power rating is 24 Volts DC, and it supports the HMI-CAB-CS11 communication cable. The unit features the RS-232 and the RS4-85 communication type. The touchscreen display is coupled to the resistive touch panel with 12-bit resolution and when it is calibrated appropriately, this translates into a grid of touch cells on the display’s face. The ES0622 display controls should be operated by using only a blunt stylus to avoid screen damage or to ensure the proper functionality of the touchscreen.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe ES0622 display supports both the hardware and the software keyboard types. For the configuration of the ES0622 display, use either of the 2 keyboards. The software keyboard, also referred to as the software emulation keyboard, is used mostly for data input when using the ES0622 display in development mode, including in the soft input panel or in the operational environment. The external keyboard is an optional device and it is supported through the ES0622 display’s universal serial board port. The ES0622 display comes with USB drivers installed, to ensure the plug and play process for the keyboard. The soft input panel (software keyboard) is preinstalled with the Windows CE operating software, and it is displayed as an icon on the taskbar system tray. The soft input panel can be dragged around the screen to ensure the visibility of the onscreen icons. The ES0622 display also supports a USB mouse that is also used for data input and control.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eManufacturer information\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGE FANUC\u003c\/strong\u003e, now part of Emerson Automation Solutions, was a leading provider of industrial automation and control systems. Known for innovative solutions, GE FANUC played a key role in advancing manufacturing, offering a range of products including PLCs, CNCs, and HMI solutions.\u003c\/p\u003e\n\u003ch5\u003eSpecifications \u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eBrand\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eGE Fanuc\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eGenius I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003ePart Number\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eIC660BBS102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eI\/O Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e115 Volts AC \/ 125 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003ePoints per Common\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e4 groups of 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFailed Switch Diagnostic\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eIsolation\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e250 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e93–132 VAC \/ 105–132 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e115 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e8.8 x 3.3 x 3.9 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eGenius Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003ePeak Heat Dissipation\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e45.6 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Response Time\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eAC: 2 ms + filter; DC: 0.8 ms + filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSelectable Input Filter Times\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eAC: 2 A RMS; DC: 2 A resistive (1 A inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eOutput Switching\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eZero crossing (OFF to ON \/ ON to OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eMax Switching Frequency\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eOnce per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eTurn-On Delay (Max)\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eAC: 0.5 Hz + 1 ms; DC: 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eBlock-to-Block Isolation\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1500 V for one minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eUnit OK, I\/O Enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"110\" data-end=\"245\" class=\"\"\u003e\n\u003cp data-start=\"112\" data-end=\"245\" class=\"\"\u003e\u003cstrong data-start=\"112\" data-end=\"141\"\u003ePurpose-Built Performance\u003c\/strong\u003e: Designed for reliable high-speed communication between the GE Series 90-70 PLC and remote I\/O devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"246\" data-end=\"348\" class=\"\"\u003e\n\u003cp data-start=\"248\" data-end=\"348\" class=\"\"\u003e\u003cstrong data-start=\"248\" data-end=\"278\"\u003eIndustry-Grade Reliability\u003c\/strong\u003e: Known for long-term durability in demanding industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"349\" data-end=\"466\" class=\"\"\u003e\n\u003cp data-start=\"351\" data-end=\"466\" class=\"\"\u003e\u003cstrong data-start=\"351\" data-end=\"380\"\u003ePlug-and-Play Integration\u003c\/strong\u003e: Seamlessly integrates with other GE Fanuc automation systems, minimizing setup time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"467\" data-end=\"577\" class=\"\"\u003e\n\u003cp data-start=\"469\" data-end=\"577\" class=\"\"\u003e\u003cstrong data-start=\"469\" data-end=\"496\"\u003eEfficient Data Handling\u003c\/strong\u003e: Supports up to 8 I\/O drops with high-speed serial communication via Genius Bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"578\" data-end=\"686\" class=\"\"\u003e\n\u003cp data-start=\"580\" data-end=\"686\" class=\"\"\u003e\u003cstrong data-start=\"580\" data-end=\"601\"\u003eSmart Diagnostics\u003c\/strong\u003e: Built-in LEDs and status indicators for quick troubleshooting and minimal downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"687\" data-end=\"770\" class=\"\"\u003e\n\u003cp data-start=\"689\" data-end=\"770\" class=\"\"\u003e\u003cstrong data-start=\"689\" data-end=\"707\"\u003eCompact Design\u003c\/strong\u003e: Space-saving module fits easily into existing GE 90-70 racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"130\" data-end=\"254\" class=\"\"\u003e\u003cstrong data-start=\"130\" data-end=\"170\"\u003eQ: What is the GE Fanuc IC697BEM733?\u003c\/strong\u003e\u003cbr data-start=\"170\" data-end=\"173\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe IC697BEM733 is a Genius Remote I\/O Scanner module designed for the GE Fanuc Series 90-70 PLC system. It facilitates communication between the central processor and remote I\/O modules over the IC66* bus.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"256\" data-end=\"388\" class=\"\"\u003e\u003cstrong data-start=\"256\" data-end=\"304\"\u003eQ: What is the maximum distance it supports?\u003c\/strong\u003e\u003cbr data-start=\"304\" data-end=\"307\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIt supports a maximum distance of 7,500 feet (2,275 meters) from the host controller, depending on the baud rate and cable type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"390\" data-end=\"513\" class=\"\"\u003e\u003cstrong data-start=\"390\" data-end=\"429\"\u003eQ: How many devices can it connect?\u003c\/strong\u003e\u003cbr data-start=\"429\" data-end=\"432\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe module can connect up to 32 devices on the bus at 153.6 Kbaud or 76.8 Kbaud, and up to 16 devices at 38.4 Kbaud.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"515\" data-end=\"631\" class=\"\"\u003e\u003cstrong data-start=\"515\" data-end=\"547\"\u003eQ: What is the I\/O capacity?\u003c\/strong\u003e\u003cbr data-start=\"547\" data-end=\"550\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIt supports up to 1,024 discrete I\/O points or 64 analog I\/O points per remote drop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"633\" data-end=\"761\" class=\"\"\u003e\u003cstrong data-start=\"633\" data-end=\"677\"\u003eQ: What types of modules are compatible?\u003c\/strong\u003e\u003cbr data-start=\"677\" data-end=\"680\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eCompatible modules include discrete and analog I\/O modules, Bus Transmitters, Bus Receivers, PCM, ADS, and analog expander modules.\u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"763\" data-end=\"891\" class=\"\"\u003e\u003cstrong data-start=\"763\" data-end=\"803\"\u003eQ: What are the communication ports?\u003c\/strong\u003e\u003cbr data-start=\"803\" data-end=\"806\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe IC697BEM733 features one 15-pin RS-422\/485 serial port and one 9-pin IC66* Hand-held Monitor port.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"893\" data-end=\"1013\" class=\"\"\u003e\u003cstrong data-start=\"893\" data-end=\"925\"\u003eQ: What is the current draw?\u003c\/strong\u003e\u003cbr data-start=\"925\" data-end=\"928\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIt requires 0.8 Amps at 5.0 Volts DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1015\" data-end=\"1153\" class=\"\"\u003e\u003cstrong data-start=\"1015\" data-end=\"1065\"\u003eQ: What is the maximum number of remote drops?\u003c\/strong\u003e\u003cbr data-start=\"1065\" data-end=\"1068\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] bg-[#FCECC1] dark:bg-[#64572A] transition-colors duration-100 ease-in-out\"\u003eIt supports up to 20 fully-loaded remote drops or up to 30 drops if not fully-loaded, depending on the baud rate.\u003c\/span\u003e\u003cspan class=\"\" data-state=\"delayed-open\" aria-describedby=\"radix-«r1c0»\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"255\" data-end=\"382\" class=\"\"\u003e\n\u003cp data-start=\"258\" data-end=\"382\" class=\"\"\u003e\u003cstrong data-start=\"258\" data-end=\"299\"\u003eRegularly Inspect for Physical Damage\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eCheck for signs of wear, corrosion, or physical damage, especially around connectors and mounting points.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"384\" data-end=\"499\" class=\"\"\u003e\n\u003cp data-start=\"387\" data-end=\"499\" class=\"\"\u003e\u003cstrong data-start=\"387\" data-end=\"416\"\u003eEnsure Proper Ventilation\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eMaintain adequate airflow around the module to prevent overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"501\" data-end=\"623\" class=\"\"\u003e\n\u003cp data-start=\"504\" data-end=\"623\" class=\"\"\u003e\u003cstrong data-start=\"504\" data-end=\"540\"\u003eVerify Secure Module Connections\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eEnsure that all modules are securely seated in their respective slots to prevent communication issues.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"625\" data-end=\"735\" class=\"\"\u003e\n\u003cp data-start=\"628\" data-end=\"735\" class=\"\"\u003e\u003cstrong data-start=\"628\" data-end=\"652\"\u003eMonitor Power Supply\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eCheck that the power supply is stable and within the specified voltage range to prevent damage to the module and connected devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"737\" data-end=\"855\" class=\"\"\u003e\n\u003cp data-start=\"740\" data-end=\"855\" class=\"\"\u003e\u003cstrong data-start=\"740\" data-end=\"770\"\u003eKeep the Environment Clean\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eRegularly clean the module to remove dust and debris, which can affect performance and cause overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"857\" data-end=\"978\" class=\"\"\u003e\n\u003cp data-start=\"860\" data-end=\"978\" class=\"\"\u003e\u003cstrong data-start=\"860\" data-end=\"891\"\u003eCheck Expansion Connections\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIf using expansion modules, ensure that the connections are secure and that the total system does not exceed the maximum supported configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"980\" data-end=\"1102\" class=\"\"\u003e\n\u003cp data-start=\"983\" data-end=\"1102\" class=\"\"\u003e\u003cstrong data-start=\"983\" data-end=\"1015\"\u003eUpdate Firmware as Necessary\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eKeep the firmware updated to ensure compatibility with other modules and to benefit from performance improvements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fanuc Corporation","offers":[{"title":"Default Title","offer_id":54165362835740,"sku":"ES0622","price":3384.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0933\/0622\/4924\/files\/ES0622.webp?v=1780291104","url":"https:\/\/www.mybackyardzone.com\/products\/es0622-ge-fanuc-6-quickpanel-view","provider":"Backup Power Made Simple","version":"1.0","type":"link"}