{"product_id":"ic660bba105-ge-fanuc-block-115vac-125vdc-analog-current-source-6-outputs","title":"Fanuc Corporation Ge Fanuc Block 115VAC\/125VDC Analog Current Source 6 Outputs - IC660BBA105","description":"\u003ch2\u003eFanuc Corporation Ge Fanuc Block 115VAC\/125VDC Analog Current Source 6 Outputs - IC660BBA105\u003c\/h2\u003e\n\u003cp\u003eThe IC660BBA105 is a Genius Block I\/O. Previously manufactured by GE Fanuc, this module is now under Emerson Automation. It is a 115 VAC\/ 125 VDC powered, stand-alone, current sourcing, analog output module that features Six (6) analog outputs that delivers 4-20 mA analog signals. This module has 6µA resolution. It supports Genius communication protocol, allowing the module to function as a stand-alone Remote I\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInformation About IC660BBA105\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe IC660BBA105 is a Genius I\/O Block component. This module is specifically an analog output module that operates at an input supply voltage of 115 VAC or 125 VDC. This module is a panel mounted device, secured through the provided mounting holes, fastened using 8-32 size screws and connected to ground using star washers. It can be installed to any enclosure, providing adequate air flow and protection to industrial contaminants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA105 mainly features Six (6) analog input channels that delivers 4-20 mA signals. Each channel has configurable output hold feature which is an important safety related functionality, allowing the module to hold the current output value in the event of processor error or change in operating mode. Additionally, individual circuit scaling to engineering values can be set to provide a usable readout. It is also capable of sensing overrange and underrange situations as well output feedback error. Output channels of this module do not require calibration to be put into operation.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA105 has output resolution of 6µA with output update frequeny of 25 ms and accuracy of 0.15% of full-scale reading. It operates at output range of 0-24 mA and thermal drift of 35 PPM per degree C typical.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eRecommended wire size for terminating field signal wires are AWG #14 (avg 2.1mm2 in cross-section) with minimum recommended size of AWG #20 (avg .54mm2 in cross-section). For serial bus wiring, recommended wire size is AWG #12 wire (avg 3.3mm2 cross-section) for single wire connection and AWG #14 wires (each avg 2.1mm2 in cross-section). When 2 wires are needed in a single terminal. Minimum recommended wire size for serial bus is AWG #22 (avg .36mm2 in cross-section).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA105 module is a Genius I-O module that is compatible with the Series 90-30 PLC system by GE Fanuc. The module has a total of 32 terminals and 6 output blocks. The resolution of the module is 6 microAmps. It comes with 6 points and the operating voltage of the module is 93 to 132 Volts AC and 105 to 145 Volts DC. The output range of the I\/O module is 4 to 20 milliAmps or 0 to 24 milliAmps. This Genius I-O analog device has an open enclosure and it should be protected against water splashes and air-borne contaminants. The IC660BBA105 module is 8.83 inches in height, 3.50 inches in width, and 3.94 inches in depth. The front of the module is equipped with a Unit OK LED and an I\/O Enabled LED.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC660BBA105 module has a block to block isolation of 1500 Volts for a time period of 1 minute. For regular operation, the I\/O module generates 12 Watts of heat as energy dissipation. The temperature of the module’s environment should not exceed 60 degrees Celsius. The IC660BBA105 module uses the monitoring port to connect with a handheld programming unit. The operating frequency of the I\/O module is 50 to 60 Hertz. It is equipped with Serial 1, Serial 2, Shield In, and Shield Out connection ports. The I\/O block has independent circuits that are electrically common but that are isolated from other circuits. The IC660BBA105 module features one of the enhanced diagnostic features in an I\/O block that can easily detect no-load errors, overload errors, short-circuit errors, and other errors. The module has a baud rate of 76.8 and 38.4 kbaud.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer information\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGe Fanuc\u003c\/strong\u003e, now part of Emerson Automation Solutions, was a leading provider of industrial automation and control systems. Known for innovative solutions, GE FANUC played a key role in advancing manufacturing, offering a range of products including PLCs, CNCs, and HMI solutions.\u003c\/p\u003e\n\u003ch5\u003eSpecifications \u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-1wig{font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-1wig\"\u003eBrand\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eGE Fanuc\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eGenius Block I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003ePart Number\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eIC660BBD110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eModule Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eDiscrete Input Block I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eDiscrete Input Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e93–132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eVoltage Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Current\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eMax. 80 mA block current plus 200 mA input circuit current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Diagnostics\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eOpen Wire, Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eFault Detection\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eShort Wire Faults, Open Wire Faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput to Ground\/Bus Isolation\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eSelectable Input Filter Times\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e10–100 ms (in 10 ms increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput Shorted Wire Threshold\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eFixed at 10%–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eInput ON\/OFF State Threshold\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eProgrammable (25% to 85%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e32°F to 140°F (0°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-1wig\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e-40°F to 212°F (-40°C to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"124\" data-end=\"247\" class=\"\"\u003e\n\u003cp data-start=\"126\" data-end=\"247\" class=\"\"\u003e\u003cstrong data-start=\"126\" data-end=\"154\"\u003ePrecision Output Control\u003c\/strong\u003e: Delivers 6 analog current outputs (0–20 mA or 4–20 mA), ideal for accurate process control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"248\" data-end=\"355\" class=\"\"\u003e\n\u003cp data-start=\"250\" data-end=\"355\" class=\"\"\u003e\u003cstrong data-start=\"250\" data-end=\"278\"\u003eDual Power Compatibility\u003c\/strong\u003e: Operates on both 115VAC and 125VDC, offering flexible installation options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"356\" data-end=\"487\" class=\"\"\u003e\n\u003cp data-start=\"358\" data-end=\"487\" class=\"\"\u003e\u003cstrong data-start=\"358\" data-end=\"387\"\u003eHeavy-Duty Industrial Use\u003c\/strong\u003e: Rugged design built for harsh environments—resistant to vibration, moisture, and electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"488\" data-end=\"629\" class=\"\"\u003e\n\u003cp data-start=\"490\" data-end=\"629\" class=\"\"\u003e\u003cstrong data-start=\"490\" data-end=\"514\"\u003eBuilt-In Diagnostics\u003c\/strong\u003e: Real-time fault detection and LED status indicators for each channel enhance reliability and ease of maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"630\" data-end=\"753\" class=\"\"\u003e\n\u003cp data-start=\"632\" data-end=\"753\" class=\"\"\u003e\u003cstrong data-start=\"632\" data-end=\"655\"\u003eModular Flexibility\u003c\/strong\u003e: Compatible with GE Genius I\/O systems, making it easy to scale or upgrade your automation setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"754\" data-end=\"867\" class=\"\"\u003e\n\u003cp data-start=\"756\" data-end=\"867\" class=\"\"\u003e\u003cstrong data-start=\"756\" data-end=\"784\"\u003eSafe \u0026amp; Isolated Channels\u003c\/strong\u003e: Individual channel isolation helps prevent cross-talk and improves system safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"137\" data-end=\"264\" class=\"\"\u003e\u003cstrong data-start=\"137\" data-end=\"177\"\u003eQ: What is the GE Fanuc IC660BBA105?\u003c\/strong\u003e\u003cbr data-start=\"177\" data-end=\"180\"\u003eA: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe IC660BBA105 is a Genius I\/O analog output module designed for GE Fanuc Series 90-30 PLCs. It provides six independent 4-20 mA current-sourcing outputs, commonly used in industrial automation applications\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"266\" data-end=\"399\" class=\"\"\u003e\u003cstrong data-start=\"266\" data-end=\"312\"\u003eQ: What are the electrical specifications?\u003c\/strong\u003e\u003cbr data-start=\"312\" data-end=\"315\"\u003eA: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIt operates on a 115 VAC or 125 VDC power supply and offers a resolution of 6 µA. The module has an accuracy of 0.15% of full-scale reading and a thermal drift of 35 PPM per degree Celsius.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"401\" data-end=\"533\" class=\"\"\u003e\u003cstrong data-start=\"401\" data-end=\"446\"\u003eQ: What is the update rate and baud rate?\u003c\/strong\u003e\u003cbr data-start=\"446\" data-end=\"449\"\u003eA: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe output update rate is 25 milliseconds, and it supports baud rates of 76.8\/38.4 kbaud for communication\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"535\" data-end=\"669\" class=\"\"\u003e\u003cstrong data-start=\"535\" data-end=\"582\"\u003eQ: What is the physical size of the module?\u003c\/strong\u003e\u003cbr data-start=\"582\" data-end=\"585\"\u003eA: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eThe module measures 22.44 cm (H) x 8.89 cm (W) x 10.00 cm (D) and weighs approximately 3.15 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"671\" data-end=\"801\" class=\"\"\u003e\u003cstrong data-start=\"671\" data-end=\"714\"\u003eQ: What are the wiring recommendations?\u003c\/strong\u003e\u003cbr data-start=\"714\" data-end=\"717\"\u003eA: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eFor field signal wires, AWG #14 (2.1 mm²) is recommended, with a minimum of AWG #20 (0.54 mm²). For serial bus wiring, AWG #12 (3.3 mm²) is recommended for single-wire connections, and AWG #14 (2.1 mm²) for dual-wire connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"803\" data-end=\"956\" class=\"\"\u003e\u003cstrong data-start=\"803\" data-end=\"865\"\u003eQ: Is the module compatible with other Genius I\/O modules?\u003c\/strong\u003e\u003cbr data-start=\"865\" data-end=\"868\"\u003eA: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eYes, the IC660BBA105 is compatible with all Genius bus controllers and can be configured using a handheld monitor (version 3.7 or later) and Logicmaster 6 software (version 4.02 or later)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"261\" data-end=\"388\" class=\"\"\u003e\n\u003cp data-start=\"264\" data-end=\"388\" class=\"\"\u003e\u003cstrong data-start=\"264\" data-end=\"305\"\u003eRegularly Inspect for Physical Damage\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eCheck for signs of wear, corrosion, or physical damage, especially around connectors and mounting points.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"390\" data-end=\"505\" class=\"\"\u003e\n\u003cp data-start=\"393\" data-end=\"505\" class=\"\"\u003e\u003cstrong data-start=\"393\" data-end=\"422\"\u003eEnsure Proper Ventilation\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eMaintain adequate airflow around the module to prevent overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"507\" data-end=\"629\" class=\"\"\u003e\n\u003cp data-start=\"510\" data-end=\"629\" class=\"\"\u003e\u003cstrong data-start=\"510\" data-end=\"546\"\u003eVerify Secure Module Connections\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eEnsure that all modules are securely seated in their respective slots to prevent communication issues.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"631\" data-end=\"741\" class=\"\"\u003e\n\u003cp data-start=\"634\" data-end=\"741\" class=\"\"\u003e\u003cstrong data-start=\"634\" data-end=\"658\"\u003eMonitor Power Supply\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eCheck that the power supply is stable and within the specified voltage range to prevent damage to the module and connected devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"743\" data-end=\"861\" class=\"\"\u003e\n\u003cp data-start=\"746\" data-end=\"861\" class=\"\"\u003e\u003cstrong data-start=\"746\" data-end=\"776\"\u003eKeep the Environment Clean\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eRegularly clean the module to remove dust and debris, which can affect performance and cause overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"863\" data-end=\"984\" class=\"\"\u003e\n\u003cp data-start=\"866\" data-end=\"984\" class=\"\"\u003e\u003cstrong data-start=\"866\" data-end=\"897\"\u003eCheck Expansion Connections\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIf using expansion modules, ensure that the connections are secure and that the total system does not exceed the maximum supported configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"986\" data-end=\"1108\" class=\"\"\u003e\n\u003cp data-start=\"989\" data-end=\"1108\" class=\"\"\u003e\u003cstrong data-start=\"989\" data-end=\"1021\"\u003eUpdate Firmware as Necessary\u003c\/strong\u003e: \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eKeep the firmware updated to ensure compatibility with other modules and to benefit from performance improvements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fanuc Corporation","offers":[{"title":"Default Title","offer_id":54165362573596,"sku":"IC660BBA105","price":3408.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0933\/0622\/4924\/files\/IC660BBA105.webp?v=1780291091","url":"https:\/\/www.mybackyardzone.com\/products\/ic660bba105-ge-fanuc-block-115vac-125vdc-analog-current-source-6-outputs","provider":"Backup Power Made Simple","version":"1.0","type":"link"}