{"product_id":"modine-commercial-effinity-heater-215k-btuhigh-efficiency-condensingdirect","title":"Modine Commercial Effinity Heater - 215K BTU\/High-Efficiency Condensing\/Direct Spark Ignition\/NG\/Separated Combustion\/Single Stage w\/Aluminized Steel Heat Exchanger - PTC215AS0111","description":"\u003ch2\u003eModine Commercial Effinity Heater - 215K BTU\/High-Efficiency Condensing\/Direct Spark Ignition\/NG\/Separated Combustion\/Single Stage w\/Aluminized Steel Heat Exchanger - PTC215AS0111\u003c\/h2\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003cli\u003eSeparated combustion - drawing combustion air from outside to ensure that the unit will always have plenty of fresh, clean air for combustion while increasing the overall heating efficiency\u003c\/li\u003e\n\u003cli\u003eHelps promote a clean air growing environment - combustion fumes are vented outside, away from your plants\u003c\/li\u003e\n\u003cli\u003eFuel savings - up to 97% efficiency allows you to save otherwise wasted energy and money\u003c\/li\u003e\n\u003cli\u003eDependable and consistent performance accompanies Modine’s Conservicore Technology - providing power exhauster and dual heat exchangers\u003c\/li\u003e\n\u003cli\u003eSecondary heat exchanger is made of AL29-4 stainless steel and comes with a 10-year warranty - eliminating corrosion concerns and extending the life of your investment\u003c\/li\u003e\n\u003cli\u003eBuilding Management System integration capabilities allow these units to be added easily to any existing system\u003c\/li\u003e\n\u003cli\u003eEnergy Saver Controls - as the temperature increases, the gas is disabled and stratified ceiling air is used to heat the space below. Once the ceiling air temperature decreases, the gas re-engages and heats the air\u003c\/li\u003e\n\u003cli\u003eContractor Convenience Package featuring a condensate pump convenience outlet, unit on\/off switch, heater function status indicator lights, and external terminals for thermostat wiring\u003c\/li\u003e\n\u003cli\u003eJust one Effinity heater can lower CO2 output by thousands of pounds annually\u003c\/li\u003e\n\u003cli\u003e4\" vent \u0026amp; combustion air connection\u003c\/li\u003e\n\u003cli\u003eNatural Gas\u003c\/li\u003e\n\u003cli\u003e215,000 BTU\u003c\/li\u003e\n\u003cli\u003eDirect spark ignition\u003c\/li\u003e\n\u003cli\u003eSingle Stage Energy Saver Controls\u003c\/li\u003e\n\u003cli\u003eAluminized steel heat exchanger\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-0lax\"\u003eFuel Type\u003c\/th\u003e\n\u003cth class=\"tg-0lax\"\u003eNatural Gas\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eControl Type\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eElectronic \/ IPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eColor \/ Finish\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eOverall Size\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e42.53\" W × 31.31\" H × 33.83\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"32\" data-end=\"196\"\u003e\n\u003cp data-start=\"34\" data-end=\"196\"\u003e\u003cstrong data-start=\"34\" data-end=\"73\"\u003eHigh-Efficiency Commercial Heating:\u003c\/strong\u003e 215,000 BTU input with condensing technology delivers exceptional efficiency, helping reduce fuel costs in large spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"197\" data-end=\"350\"\u003e\n\u003cp data-start=\"199\" data-end=\"350\"\u003e\u003cstrong data-start=\"199\" data-end=\"231\"\u003eSeparated Combustion Design:\u003c\/strong\u003e Draws fresh air from outside for cleaner, safer operation—ideal for warehouses, workshops, and commercial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"351\" data-end=\"470\"\u003e\n\u003cp data-start=\"353\" data-end=\"470\"\u003e\u003cstrong data-start=\"353\" data-end=\"388\"\u003eReliable Direct Spark Ignition:\u003c\/strong\u003e Ensures consistent starts and dependable performance in demanding environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"471\" data-end=\"585\"\u003e\n\u003cp data-start=\"473\" data-end=\"585\"\u003e\u003cstrong data-start=\"473\" data-end=\"500\"\u003eDurable Heat Exchanger:\u003c\/strong\u003e Aluminized steel construction provides corrosion resistance and long service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"586\" data-end=\"673\"\u003e\n\u003cp data-start=\"588\" data-end=\"673\"\u003e\u003cstrong data-start=\"588\" data-end=\"615\"\u003eSingle-Stage Operation:\u003c\/strong\u003e Simple, proven design for steady, reliable heat output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"674\" data-end=\"777\"\u003e\n\u003cp data-start=\"676\" data-end=\"777\"\u003e\u003cstrong data-start=\"676\" data-end=\"703\"\u003eVersatile Applications:\u003c\/strong\u003e Well-suited for industrial, agricultural, and commercial heating needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"778\" data-end=\"921\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"780\" data-end=\"921\" data-is-last-node=\"\"\u003e\u003cstrong data-start=\"780\" data-end=\"805\"\u003eStrong Market Appeal:\u003c\/strong\u003e High demand for efficient, condensing natural gas unit heaters that balance power, reliability, and energy savings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"121\" data-end=\"271\"\u003e\u003cstrong data-start=\"121\" data-end=\"175\"\u003eQ: What type of heater is the Modine PTC215AS0111?\u003c\/strong\u003e\u003cbr data-start=\"175\" data-end=\"178\"\u003eA: A commercial high-efficiency condensing natural gas unit heater for large indoor spaces.\u003c\/p\u003e\n\u003cp data-start=\"273\" data-end=\"368\"\u003e\u003cstrong data-start=\"273\" data-end=\"309\"\u003eQ: What is its heating capacity?\u003c\/strong\u003e\u003cbr data-start=\"309\" data-end=\"312\"\u003eA: 215,000 BTU input for powerful, consistent heating.\u003c\/p\u003e\n\u003cp data-start=\"370\" data-end=\"511\"\u003e\u003cstrong data-start=\"370\" data-end=\"404\"\u003eQ: How energy-efficient is it?\u003c\/strong\u003e\u003cbr data-start=\"404\" data-end=\"407\"\u003eA: High-efficiency condensing design delivers up to 90%+ thermal efficiency to reduce operating costs.\u003c\/p\u003e\n\u003cp data-start=\"513\" data-end=\"615\"\u003e\u003cstrong data-start=\"513\" data-end=\"553\"\u003eQ: What ignition system does it use?\u003c\/strong\u003e\u003cbr data-start=\"553\" data-end=\"556\"\u003eA: Direct spark ignition for reliable, efficient startup.\u003c\/p\u003e\n\u003cp data-start=\"617\" data-end=\"746\"\u003e\u003cstrong data-start=\"617\" data-end=\"660\"\u003eQ: What does separated combustion mean?\u003c\/strong\u003e\u003cbr data-start=\"660\" data-end=\"663\"\u003eA: It draws combustion air from outside, improving indoor air quality and safety.\u003c\/p\u003e\n\u003cp data-start=\"748\" data-end=\"879\"\u003e\u003cstrong data-start=\"748\" data-end=\"792\"\u003eQ: What heat exchanger material is used?\u003c\/strong\u003e\u003cbr data-start=\"792\" data-end=\"795\"\u003eA: Durable aluminized steel for long-lasting performance and corrosion resistance.\u003c\/p\u003e\n\u003cp data-start=\"881\" data-end=\"1011\"\u003e\u003cstrong data-start=\"881\" data-end=\"923\"\u003eQ: Where is this heater commonly used?\u003c\/strong\u003e\u003cbr data-start=\"923\" data-end=\"926\"\u003eA: Ideal for warehouses, garages, workshops, greenhouses, and commercial buildings.\u003c\/p\u003e\n\u003cp data-start=\"1013\" data-end=\"1126\"\u003e\u003cstrong data-start=\"1013\" data-end=\"1039\"\u003eQ: Is it single stage?\u003c\/strong\u003e\u003cbr data-start=\"1039\" data-end=\"1042\"\u003eA: Yes, single-stage operation for dependable and straightforward heating control.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul data-start=\"218\" data-end=\"1049\"\u003e\n\u003cli data-start=\"218\" data-end=\"326\"\u003e\n\u003cp data-start=\"220\" data-end=\"326\"\u003e\u003cstrong data-start=\"220\" data-end=\"240\"\u003eKeep Unit Clean:\u003c\/strong\u003e Wipe exterior surfaces regularly to prevent dust buildup that can restrict airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"327\" data-end=\"468\"\u003e\n\u003cp data-start=\"329\" data-end=\"468\"\u003e\u003cstrong data-start=\"329\" data-end=\"356\"\u003eInspect Heat Exchanger:\u003c\/strong\u003e Periodically check the aluminized steel heat exchanger for dirt, corrosion, or damage to maintain efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"469\" data-end=\"571\"\u003e\n\u003cp data-start=\"471\" data-end=\"571\"\u003e\u003cstrong data-start=\"471\" data-end=\"494\"\u003eBurner Maintenance:\u003c\/strong\u003e Inspect and clean burner assemblies to ensure clean, efficient combustion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"572\" data-end=\"685\"\u003e\n\u003cp data-start=\"574\" data-end=\"685\"\u003e\u003cstrong data-start=\"574\" data-end=\"600\"\u003eIgnition System Check:\u003c\/strong\u003e Verify proper operation of the direct spark ignition system for reliable startups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"686\" data-end=\"801\"\u003e\n\u003cp data-start=\"688\" data-end=\"801\"\u003e\u003cstrong data-start=\"688\" data-end=\"712\"\u003eGas Line Inspection:\u003c\/strong\u003e Check gas connections and fittings for leaks or looseness; address issues immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"802\" data-end=\"924\"\u003e\n\u003cp data-start=\"804\" data-end=\"924\"\u003e\u003cstrong data-start=\"804\" data-end=\"834\"\u003eVenting \u0026amp; Condensate Care:\u003c\/strong\u003e Keep intake and exhaust vents clear and ensure condensate drains are free of blockages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"925\" data-end=\"1049\"\u003e\n\u003cp data-start=\"927\" data-end=\"1049\"\u003e\u003cstrong data-start=\"927\" data-end=\"959\"\u003eAnnual Professional Service:\u003c\/strong\u003e Schedule yearly service by a qualified technician for safety checks and peak performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Modine","offers":[{"title":"Default Title","offer_id":45468045148351,"sku":"PTC215AS0111","price":5361.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/modine-commercial-effinity-heater-215k-btuhigh-efficiency-condensingdirect-spark-783.webp?v=1775545234","url":"https:\/\/www.mybackyardzone.com\/products\/modine-commercial-effinity-heater-215k-btuhigh-efficiency-condensingdirect","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}