The Wilkins 950XLT 1" Top-Access Double-Check Valve Assembly is a durable, serviceable backflow preventer designed for low-hazard irrigation and non-potable water applications. Its compact top-access design allows testing and maintenance while fitting inside standard meter boxes, making it ideal for below-grade installations.

Designed to protect potable systems from backpressure and backsiphonage, the 950XLT offers long-term reliability with replaceable internals to reduce lifecycle costs. Its compact footprint and corrosion-resistant materials make it well suited for meter box installations where easy access for annual testing is required. For complete dimensions, installation instructions and parts lists, refer to the product specification sheet included in the product documents. Routine maintenance is limited to periodic testing and replacement of worn seats or seals; use only manufacturer-approved replacement parts and follow local codes for backflow device testing and certification.

Features
  • Size & connections: 1" FNPT x FNPT connections for standard threaded piping.
  • Robust construction: Cast bronze main body and cast bronze access covers for corrosion resistance.
  • Internal components: Stainless-steel internals and springs with replaceable seats and silicone or Buna-N seal rings.
  • Operating limits: Maximum working pressure 175 PSI and maximum working temperature 180°F; hydrostatic test 350 PSI.
  • Serviceability: Top-access check covers and full-port ball valves simplify testing, repair, and winterization.
  • Approvals: ASSE 1015, IAPMO, CSA and AWWA C510 listings; approved by the USC Foundation for Cross-Connection Control and Hydraulic Research.
What our Experts Think
  • Reliable low-hazard protection: The Zurn Wilkins 1" 950XLT Double Check Valve Assembly (1-950XLT) is designed to prevent backsiphonage and backpressure in non-health-hazard potable and irrigation systems.
  • Top-access maintenance design: Features top-access check covers, allowing servicing of internal components without removing the entire valve from the line—reducing downtime and labor.
  • Built for long service life: Constructed with a cast bronze body, stainless steel springs, and corrosion-resistant internal hardware for durability in outdoor and below-grade installations.
  • Compact, installation-friendly layout: Designed to fit standard valve boxes, making it ideal for residential and light commercial irrigation systems where space is limited.
  • Serviceable internals: Includes replaceable seats and seal rings, helping extend product life and reduce long-term maintenance costs.
  • Code-compliant performance: Meets common industry standards including ASSE 1015, CSA, cUPC, and AWWA compliance, supporting approved installations in most jurisdictions.
  • Pro-grade reliability: Rated for up to 175 PSI working pressure and 180°F maximum temperature, making it suitable for typical municipal supply conditions.

Q&A

Q: What is the Zurn Wilkins 1-950XLT 1" Top-Access Double Check Valve Assembly?
A: The Zurn Wilkins 1-950XLT is a 1-inch lead-free double check valve assembly designed to prevent backflow contamination in low-hazard (non-health hazard) potable water systems by stopping backpressure and backsiphonage.

Q: What applications is the 1-950XLT used for?
A: It is commonly used in irrigation systems, fire sprinkler loops, and commercial or residential plumbing where cross-connection protection is needed but a reduced pressure zone device is not required.

Q: What are the key features of the 950XLT series?
A: It includes a top-access design for easy maintenance, replaceable seats and seals, corrosion-resistant stainless steel internals, and a compact wye-pattern body suitable for meter boxes and below-grade installations.

Q: What are its performance ratings?
A: The valve typically handles up to 175 PSI working pressure and 180°F maximum temperature, with hydrostatic test pressure up to 350 PSI.

Q: Is the Zurn Wilkins 1-950XLT ?
A: Yes. It is listed to major standards including ASSE 1015, IAPMO/CSA listings, and AWWA compliance for approved backflow protection in non-health hazard applications. 


Maintenance Tips
  • Schedule annual certified testing to confirm proper backflow prevention and compliance.
  • Inspect regularly for leaks, corrosion, or abnormal pressure loss, especially after system changes.
  • Keep shutoff valves and test cocks clean and fully functional to ensure accurate testing.
  • Flush the line periodically to reduce sediment buildup inside the valve body.
  • Protect from freezing conditions using insulation or seasonal drainage where applicable.
  • Use only genuine repair parts from Zurn Wilkins to maintain performance and certification.
  • After servicing, re-test the assembly before restoring water service.