Actron Air CRE-125AS / URC-125AS 12.5kW Cassette Split System - CRE-125AS

Introducing the Actron Air CRE-125AS / URC-125AS 12.5kW Cassette Split System, a pinnacle of efficient climate control for your commercial and residential spaces. This robust system boasts a powerful 12.5kW cooling and 14.5kW heating capacity, ensuring optimal comfort all year round. Designed with premium Australian engineering, it features a sleek cassette design that blends seamlessly into any environment. Equipped with a premium wired controller, the system offers precise climate management at your fingertips. Experience superior performance and reliability with the Actron Air Cassette Split System.

What our Experts Think
  • High-capacity cassette system: 12.5kW cooling power delivers strong performance for large open-plan areas, offices, retail spaces, or multi-zone rooms
  • 360° air distribution: 4-way cassette design ensures even airflow in all directions, reducing hot and cold spots
  • Powerful heating & cooling range: Approx. 12.5kW cooling / 14.5kW heating, suitable for year-round commercial or large residential comfort 
  • High airflow output: Up to 511 L/s airflow, ensuring fast temperature pull-down in large spaces 
  • Efficient inverter operation: Twin-rotary DC inverter compressor delivers stable temperatures with reduced energy consumption
  • Quiet indoor performance for its size: Indoor sound levels around 47–53 dB(A) depending on fan speed 
  • Advanced airflow control: Independent louvre adjustment and memory function for custom comfort direction
  • Built-in drain pump: Helps manage condensate efficiently for flexible ceiling installation
  • Wide operating range: Performs in extreme climates from -15°C to 50°C cooling conditions 
  • Smart protection systems: Includes auto diagnostics, fire-proof electrical box, and coil protection for long-term reliability

Q&A

Q: What is the ActronAir CRE-125AS / URC-125AS cassette split system?
A: The ActronAir CRE-125AS / URC-125AS is a 12.5kW reverse-cycle cassette split system designed for discreet ceiling installation, delivering powerful cooling and heating for large residential or commercial spaces.

Q: What size area is it suitable for?
A: With a 12.5kW cooling capacity, it is suitable for large open-plan living areas, offices, retail spaces, or commercial rooms requiring strong airflow distribution.

Q: Is it a heating and cooling system?
A: Yes, it is a reverse-cycle system, providing both cooling in summer and heating in winter through a single cassette indoor unit.

Q: What type of installation does it use?
A: It is a 4-way ceiling cassette system, installed flush into the ceiling so only the grille is visible, offering a clean and modern appearance.

Q: How does the airflow work?
A: It provides 360° air distribution with adjustable louvres, ensuring even temperature coverage across large spaces.

Q: Is it energy efficient?
A: Yes, it uses an inverter twin-rotary compressor, adjusting output based on demand to improve efficiency and reduce running costs.

Q: Does it operate quietly?
A: Yes, cassette systems are designed for low indoor noise levels, since the main mechanical components are installed in the ceiling space and outdoor unit.

Q: Is this a complete system?
A: Yes, it includes both the CRE-125AS indoor cassette unit and URC-125AS outdoor unit, forming a complete split system. 


Maintenance Tips
  • Clean return air filter monthly: Prevents airflow restriction, improves efficiency, and reduces compressor load.
  • Inspect and clean 4-way cassette panel: Keep louvers and 360° airflow outlets dust-free for even cooling/heating distribution.
  • Check condensate drain pump: Ensure it’s clear and operating properly to avoid water overflow or ceiling leaks. 
  • Vacuum indoor coil yearly: Removes dust buildup that reduces cooling capacity and increases power consumption.
  • Keep return air path unobstructed: Critical for maintaining high airflow (up to ~511 L/s) and system balance.
  • Inspect outdoor unit (URC-125AS): Clear leaves, dust, and debris around condenser for proper heat exchange.
  • Check refrigerant lines & insulation: Look for cracks or leaks that reduce efficiency or cause icing issues.
  • Monitor airflow noise changes: Early sign of clogged filters, fan imbalance, or drainage issues.
  • Annual professional service: Clean coils, test drain pump, verify electrical safety, and check refrigerant performance