Skip to product information
1 of 10

Chattanooga

Chattanooga Vectra Genisys Laser Transport Therapy - DJO-2784

Chattanooga Vectra Genisys Laser Transport Therapy - DJO-2784

review stars 1 Review

25% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $2,067.25 Sale price $1,550.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$22.99

$70.00

$52.99

Add-Ons Bundle

$30.00

$22.99

$70.00

$52.99

Bundle Offer

$100.00

$75.98

Recently Viewed

Chattanooga Vectra Genisys Laser Transport Therapy - DJO-2784

The Chattanooga Vectra Genisys Laser Transport Therapy (#2784) is a Class 3B Low Level laser Therapy system with independent controls over all parameters. It comes with two pairs of the Laser Protection Glasses (#27525), an interrupt switch, and the User Manual on CD (#28066).

The Chattanooga Vectra Genisys Laser Transport Therapy allows for continuous and pulsed operation, with fully variable pulsed frequencies and real time feedback of delivered energy during the procedure. It's compatible with a variety of laser diode applicators, for better response to patient issues. The system is also equipped with a menu of clinical indications depending on the chosen diode applicator.

This Laser Therapy system has 15 user-defined memory slots for storage and a backlit LCD display for better visibility in low light scenarios. The device can be mounted to a cart, table top, wall, or for mobile use.

Features

 Features
  • Can be mounted to a cart, table top, or wall.
  • 15 user-defined memory slots.
  • Compatible with 8 applicators (sold separately).
  • Get real time feedback of energy delivered during treatment.

Specifications

 Accessories
  • #27467: Carry Bag.
  • #27478: Battery Pack.
  • #2883: Cart Adapter.
  • #2775ASY: Therapy Cart.
  • #27840: Single Diode Applicator 100 mW total power, Laser Diode 1 x 850 nm.
  • #27841: Single Diode Applicator 200 mW total power, Laser Diode 1 x 850 nm.
  • #27805: Single Diode Applicator 300 mW total power, Laser Diode 1 x 820 nm.
  • #27811: 9 Cluster Diode Applicator 540 mW total power, LEDs: 4 x 670 nm/10 mW, Laser Diodes: 5 x 850 nm/100 mW.
  • #27812: 9 Cluster Diode Applicator 1040 mW total power, LEDs: 4 x 670 nm/10 mW, Laser Diodes: 5 x 850 nm/200 mW.
  • #27814: 13 Cluster Diode Applicator 415 mW total power, LEDs: 7 x 670 nm/10 mW, SLDs: 3 x 950 nm/15 mW, Laser Diodes: 3 x 850 nm/100 mW.
  • #27816: 13 Cluster Diode Applicator 715 mW total power, LEDs: 7 x 670 nm/10 mW, SLDs: 3 x 950 nm/15 mW, Laser Diodes: 3 x 850 nm/200 mW.
  • #27808: 33 Cluster Diode Applicator 1440 mW total power, LEDs: 12 x 670 nm/10 mW, SLDs: 8 x 880 nm/25 mW | 8 x 950 nm/15 mW, Laser Diodes: 5 x 850 nm/200 mW.

Literature

 Literature

Chattanooga Vectra Genisys Electrotherapy Products Catalog

Chattanooga Vectra Genisys Laser System Brochure

What our Experts Think
  • Professional-grade laser therapy platform – A Class 3B low-level laser therapy (LLLT) system designed for clinics seeking precise, non-invasive pain management and rehabilitation treatments.
  • Highly customizable treatments – Supports continuous and pulsed therapy modes, adjustable treatment parameters, and real-time energy feedback for accurate dosage delivery.
  • Expandable for multiple applications – Compatible with 8 interchangeable laser diode and cluster applicators (sold separately), allowing clinicians to tailor treatments for different conditions and tissue depths.
  • Optimized clinical workflow – Includes preset clinical indications plus user-defined protocol memory for faster setup and consistent treatment sessions.
  • Portable and clinic-ready – Compact design supports tabletop, wall-mount, cart, or mobile operation, making it ideal for multi-room practices and on-the-go therapy. Laser applicator sold separately.

Q&A

Q: What is the Chattanooga Vectra Genisys Laser Transport Therapy (DJO-2784)?
A: It is a professional Class 3B low-level laser therapy (LLLT) system designed to deliver customizable laser treatments for pain management and rehabilitation.

Q: Does this system include a laser applicator?
A: No. The DJO-2784 includes the laser control unit only. Laser diode and cluster applicators are sold separately.

Q: What treatment modes are available?
A: The system offers continuous and pulsed laser therapy with independent parameter control and real-time dosage feedback.

Q: Which laser applicators are compatible?
A: The unit supports up to eight interchangeable Chattanooga laser diode and cluster applicators ranging from 100 mW to 1440 mW.

Q: What accessories are included?
A: The package includes two pairs of laser protective eyewear, a patient stop switch (interlock), and a user manual on CD.

Q: Who is this laser therapy system intended for?
A: It is designed for licensed healthcare professionals in physical therapy, chiropractic, sports medicine, and rehabilitation clinics


Maintenance Tips
  • Clean the laser head and applicator lens before each use using approved cleaning products and a soft, lint-free cloth to maintain optimal laser performance.
  • Wipe the unit housing with a damp cloth or mild cleaner, and clean accessories with soap and water only; avoid abrasive or chlorine-based cleaners.
  • Inspect the power cord, applicator cable, and lens regularly for wear, damage, or debris; replace damaged components before use.
  • Keep the device dry, prevent liquids from entering the unit, and store it in a clean, dust-free environment when not in use.
  • Remove the battery if the unit will be stored for an extended period to help preserve battery life.
  • Schedule annual applicator calibration and preventive service through an authorized service provider to ensure safe, accurate operation.