Skip to product information
1 of 10

Cooper & Hunter

Cooper & Hunter 6 Zone 48,000 BTU One-Way Cassette Mini Split AC R454B 6K+6K+9K+9K+9K+9K - CH-R48MES-230VO06MCT1W06MCT1W09MCT1W09MCT1W09MCT1W09MCT1W

Cooper & Hunter 6 Zone 48,000 BTU One-Way Cassette Mini Split AC R454B 6K+6K+9K+9K+9K+9K - CH-R48MES-230VO06MCT1W06MCT1W09MCT1W09MCT1W09MCT1W09MCT1W

review stars 1 Review

39% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $12,415.86 Sale price $9,311.99
Shipping calculated at checkout.
Line Set Length

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$22.99

$70.00

$52.99

Add-Ons Bundle

$30.00

$22.99

$70.00

$52.99

Bundle Offer

$100.00

$75.98

Recently Viewed

Cooper & Hunter 6 Zone 48,000 BTU One-Way Cassette Mini Split AC R454B 6K+6K+9K+9K+9K+9K - CH-R48MES-230VO06MCT1W06MCT1W09MCT1W09MCT1W09MCT1W09MCT1W

The Cooper & Hunter 6-Zone Mini Split System features a 48,000 BTU capacity, 24 SEER2 efficiency, and built-in Wi-Fi control for seamless temperature management across six zones. It utilizes R454B refrigerant and operates effectively in heating conditions as low as -13°F, ensuring reliable performance in colder climates.

Features
  • 6-zone system — the CH-R48MES-230VO outdoor unit supports up to 6 independently controlled indoor units; port adapters included, no branch boxes required
  • 48,000 BTU nominal system capacity across 6 zones, each on its own remote
  • 24 SEER2 inverter efficiency — current R454B generation
  • Heat pump — heats down to -13°F outdoor ambient
  • R454B refrigerant, factory pre-charged; built-in Wi-Fi control
  • Mix any Cooper & Hunter head types — wall mount, ceiling cassette, slim duct, floor/ceiling console
  • Outdoor unit (condenser): CH-R48MES-230VO — 48000 BTU R454B multi-zone outdoor unit
  • Up to 6 indoor units — configured to your selected zones (wall-mount, cassette, slim-duct, or console), each with a remote control
  • Line-set kits — choose copper line-set length per zone at checkout (or supply your own)
Specifications
Power Supply 208/230V, 1 Ph, 60 Hz (voltage range 187-253V)
Cooling — Rated Capacity (Range) 60,000 Btu/h (19,000–62,000)
Heating at 47°F — Rated Capacity (Range) 60,000 Btu/h (20,000–60,000)
Rated Heating at 5°F 39,000 Btu/h
SEER2 / EER2 22 / 10
HSPF4 / HSPF5 / COP (47°F) 9.5 / 7.4 / 3.7
Outdoor Unit MCA / Max. Fuse 36 A / 40 A
Max. Connectable Indoor Units 6
Outdoor Noise Level 65 dB(A)
Outdoor Unit Dimensions (W×D×H) 37.48 × 16.34 × 52.48 in
Outdoor Unit Net / Gross Weight 237.88 / 270.28 lbs
Refrigerant Type / Charge R454B / 151.68 oz
Pre-charged Line Length 150 ft (add 0.16 oz/ft for 1/4 in liquid pipe / 0.32 oz/ft for 3/8 in liquid pipe)
Max. Total Pipe Length / Max. to One Indoor 262.4 ft / 114.8 ft
Max. Height Difference (Indoor–Outdoor / Between Indoors) 49.2 ft / 33 ft
Operating Range — Cooling / Heating -13–122°F / -13–75°F outdoor ambient
What our Experts Think
  • Efficient multi-zone comfort: The Cooper & Hunter 48,000 BTU 6-Zone One-Way Cassette Mini Split system delivers reliable cooling and heating for homes, offices, and multi-room spaces.
  • Flexible 6-zone configuration: The 6K + 6K + 9K + 9K + 9K + 9K BTU setup allows customized temperature control across multiple areas for personalized comfort.
  • Space-saving cassette design: One-way ceiling cassette indoor units provide a sleek, low-profile installation while distributing air efficiently throughout each zone.
  • Advanced inverter technology: The system adjusts output based on room demand to help maintain stable temperatures, improve efficiency, and reduce energy waste.
  • Eco-friendly R454B refrigerant: Built with next-generation R454B refrigerant for enhanced environmental performance and a lower global warming impact.
  • Ideal for modern spaces: Perfect for renovations, new construction, offices, and properties where a clean ceiling-mounted solution is preferred over traditional wall units.
  • Year-round climate control: Heat pump functionality provides dependable cooling in warm seasons and heating during colder months.
  • Expert recommendation: A premium choice for customers who need discreet installation, multiple comfort zones, and efficient ductless heating and cooling performance.

Q&A

Q: What is the cooling capacity of the Cooper & Hunter 6-Zone One-Way Cassette Mini Split System?
A: This system provides 48,000 BTU of cooling capacity for efficient multi-room heating and cooling performance.

Q: How many zones can this mini split system control?
A: It supports up to 6 independent zones, allowing customized temperature control throughout multiple rooms or areas.

Q: What indoor units are included in this package?
A: This configuration includes six one-way cassette indoor units rated 6K+6K+9K+9K+9K+9K BTU for flexible zone comfort.

Q: Does this system provide both heating and cooling?
A: Yes, it is a ductless mini split heat pump designed for year-round air conditioning and heating.

Q: What refrigerant does this Cooper & Hunter mini split use?
A: It uses R454B refrigerant, a modern lower-GWP refrigerant for improved environmental performance.

Q: What voltage is required for installation?
A: This system operates on 208-230V, single-phase, 60Hz electrical power.

Q: Is this a ductless one-way cassette mini split system?
A: Yes, the ceiling cassette design provides discreet installation while delivering efficient zoned heating and cooling without traditional ductwork.

Q: Can each zone be controlled separately?
A: Yes, the 6-zone setup allows individual comfort settings for different rooms and spaces.

Q: Does this system use inverter technology?
A: Yes, inverter technology helps maintain consistent temperatures while improving energy efficiency.


Maintenance Tips
  • Clean or replace air filters regularly to maintain efficient airflow and indoor air quality.
  • Clean cassette panels, vents, and louvers to prevent dust buildup and improve air distribution.
  • Keep the outdoor condenser unit clear of leaves, dirt, and debris for proper airflow.
  • Clean condenser coils periodically to support efficient cooling and heating.
  • Inspect refrigerant lines and connections for leaks or signs of wear.
  • Check and clean condensate drains to prevent clogs and water leaks.
  • Keep ceiling cassette air outlets unobstructed for balanced temperature control.
  • Monitor system performance and listen for unusual sounds or changes in operation.
  • Schedule professional maintenance periodically to improve efficiency and extend system life.