Skip to product information
1 of 10

PCE

PCE Particle Counter Air Sampler - MPC 10

PCE Particle Counter Air Sampler - MPC 10

review stars 1 Review

25% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $648.90 Sale price $486.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$22.99

$70.00

$52.99

Add-Ons Bundle

$30.00

$22.99

$70.00

$52.99

Bundle Offer

$100.00

$75.98

Recently Viewed

PCE  Particle Counter Air Sampler - MPC 10

    The PCE MPC 10 Particle Counter Air Sampler is a portable device designed to monitor particulate matter (PM) concentrations in the air. Ideal for indoor air quality (IAQ) assessments, it also measures air temperature and relative humidity (RH). Powered by either a rechargeable battery or USB port, the USB port is also used for charging the battery. The device continues to take measurements while charging, ensuring uninterrupted IAQ monitoring. Featuring an integrated data logger, it offers adjustable sampling times of 30 seconds, 1 minute, 2 minutes, or 5 minutes, and can store up to 5,000 date-and-time-stamped data sets in its internal memory.

    The particle counter displays all measurements simultaneously on the device's 2" full-color LCD screen. Temperature units can be shown in either degrees Celsius (°C) or Fahrenheit (°F). A scale below the measured values provides a visual warning via a band of colors increasing from green (safe) to violet (extreme danger). This visual color-coding system makes it easy to recognize when PM concentration levels become dangerous, allowing for quick action.

    When inhaled, PM 2.5 and PM 10 particles can settle deep into the lungs and result in damaging health effects. Since the PCE-MPC 10 particle counter monitors PM 2.5 and PM 10 particles, the device has many practical health and safety applications. Heating, ventilation and air conditioning (HVAC) technicians use PM 2.5 and PM 10 particle counters for HVAC system performance and filtration audits. In addition, industrial hygienists and workplace safety professionals rely on PM 2.5 and PM 10 particle counters when evaluating occupational health and safety risks related to hazardous and combustible dust.

    Features
    • Particulate matter (PM) channels: PM 2.5, PM 10
    • Particle sizes (in micrometers): 2.5 µm, 10 µm
    • Temperature measuring range: 0 - +50 °C / +32 - +122 °F
    • Humidity measuring range: 0 - 100 % RH
    • 2" full-color LCD with user-friendly graphics
    • 220 x 176 pixel display resolution
    • Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)
    • Powered by rechargeable battery or AC power (via USB port)
    • Portable handheld design for indoor air quality (IAQ) monitoring in the field and on the go
    • Includes a stand for attaching to the thread on the back of the device
    • Features an internal memory for storing up to 5000 data sets
    • Saved data is stamped with the time and date
    • Takes measurements even while the battery is charging
    • Integrated data logger with adjustable sampling time: 30 seconds, 1 minute, 2 minutes or 5 minutes
    • Programmable alarm and automatic power-off battery-saving functionality
    Highlights:
    • Portable
    • Handheld
    • Particle counter for monitoring particulate matter (PM) concentrations in the air.
    • 2.5 µm and 10 µm particle sizes.
    • Measures air temperature and relative humidity.
    • Internal memory stores up to 5000 date-and-time-stamped data sets.
    • Integrated data logger with adjustable sampling time.
    What our Experts Think
    • Reliable Airborne Particle Monitoring – The PCE-MPC 10 provides accurate particle counting and air sampling to help maintain clean and controlled environments.
    • Ideal for Quality-Critical Industries – Suitable for cleanrooms, laboratories, pharmaceutical production, healthcare facilities, and manufacturing environments where air cleanliness is essential.
    • Fast & Consistent Measurements – Delivers dependable particle data for effective contamination monitoring and environmental quality control.
    • Portable & Easy to Use – Compact design enables convenient on-site inspections, routine testing, and air quality assessments across multiple locations.
    • Supports Compliance & Contamination Control – Helps organizations maintain cleanliness standards, reduce contamination risks, and improve quality assurance processes.
    Q&A

    Q: What is the PCE-MPC 10 Particle Counter Air Sampler used for?
    A: The PCE-MPC 10 is designed to detect and measure airborne particle concentrations for air quality monitoring, contamination control, and environmental testing.

    Q: Where is the PCE-MPC 10 commonly used?
    A: It is ideal for cleanrooms, laboratories, pharmaceutical facilities, healthcare environments, manufacturing plants, and HVAC system inspections.

    Q: Can the PCE-MPC 10 help maintain cleanroom standards?
    A: Yes. It supports cleanroom validation, environmental monitoring, and contamination control by accurately measuring airborne particles.

    Q: Does the PCE-MPC 10 support data logging?
    A: Yes. The device allows measurement data to be stored and reviewed for reporting, compliance documentation, and trend analysis.

    Q: Is the PCE-MPC 10 portable?
    A: Yes. Its compact design makes it suitable for both on-site inspections and routine air quality assessments.

    Q: Why choose the PCE-MPC 10 Particle Counter Air Sampler?
    A: It provides reliable particle monitoring, accurate measurements, and user-friendly operation for professional air quality and contamination assessment.

    Maintenance Tips
    • Keep the sampling inlet clean and free from dust, debris, and obstructions to ensure accurate particle measurements.
    • Perform regular calibration checks to maintain reliable counting accuracy and instrument performance.
    • Inspect and maintain filters as recommended to preserve proper airflow and sampling efficiency.
    • Store the instrument in a clean, dry environment away from moisture, excessive heat, and direct sunlight.
    • Use the protective carrying case during transport and storage to prevent physical damage.
    • Handle with care and avoid drops, impacts, or excessive vibration that may affect sensor accuracy.
    • Keep the battery properly charged for dependable operation during field and laboratory testing.
    • Verify airflow performance periodically to ensure consistent sampling results.
    • Back up measurement data regularly and keep software updated when applicable