Skip to product information
1 of 10

Zurn

Zurn Wilkins 112-975XL Reduced Pressure Backflow Preventer - 1-1/2 in - 112-975XL

Zurn Wilkins 112-975XL Reduced Pressure Backflow Preventer - 1-1/2 in - 112-975XL

review stars 1 Review

25% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $1,674.99 Sale price $1,256.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$22.99

$70.00

$52.99

Add-Ons Bundle

$30.00

$22.99

$70.00

$52.99

Bundle Offer

$100.00

$75.98

Recently Viewed

Zurn Wilkins 112-975XL Reduced Pressure Backflow Preventer - 1-1/2 in - 112-975XL

The Wilkins 112-975XL (975XL series) Reduced Pressure Principle backflow preventer provides reliable high-hazard protection for potable water systems. Designed for irrigation, commercial, and fire-protection applications, this serviceable assembly combines a cast bronze wye-pattern body with corrosion-resistant internals for durability and easy maintenance.

Includes manufacturer specification sheet, installation and maintenance instructions, and parts lists. Order includes the backflow assembly only; valves, adapters, and additional accessories sold separately. For repair kits and detailed service procedures, consult Zurn Wilkins documentation or contact a certified installer.

Features
  • Model/SKU: 112-975XL (975XL series), nominal size 1-1/2 in, threaded FNPT end connections for standard pipe fittings.
  • Performance: 175 psi maximum operating pressure; temperature rating to 180°F; hydrostatic test 350 psi (typical).
  • Construction: Cast bronze wye-pattern body with stainless-steel fasteners and springs; replaceable check and relief valve seats.
  • Serviceability: Top-access checks and relief valve for simplified on-site maintenance; compatible repair kits available to extend service life.
  • Installation benefits: Wye-pattern and short lay length reduce installation space and labor; suitable for domestic irrigation, commercial plumbing, and fire-protection lines.
  • Compliance: Manufactured to industry standards and listings (ASSE, IAPMO, AWWA where applicable); follow local codes for approved installations.
What our Experts Think
  • High-hazard RPZ protection: The Zurn Wilkins 112-975XL is a 1-1/2" Reduced Pressure Principle (RPZ) backflow preventer designed to protect potable water systems from both back-siphonage and backpressure contamination.
  • Critical safety performance: Built for applications where water safety is essential—such as irrigation, commercial plumbing, and fire protection systems requiring high-level cross-connection control.
  • Durable bronze construction: Heavy-duty cast bronze body with corrosion-resistant internal components ensures long service life in demanding commercial environments.
  • Service-friendly wye design: Wye-pattern layout with separate access to check valves and relief valve simplifies maintenance and reduces downtime during servicing.
  • Compact installation footprint: Short lay length makes it easier to install or replace in tight mechanical spaces without major system modification.
  • Code-compliant reliability: Commonly specified for systems requiring ASSE 1013 compliance and approval under major plumbing and water safety standards.
  • Contractor-trusted choice: Widely used by professionals for its proven durability, predictable performance, and ease of field maintenance in high-risk potable water applications.

Q&A

Q: What is the Zurn Wilkins 112-975XL Reduced Pressure Backflow Preventer 1-1/2 in used for?
A: It provides high-hazard backflow protection in potable water systems, preventing contaminated water from entering the clean water supply in applications like irrigation, commercial plumbing, and fire protection lines.

Q: What type of device is the 112-975XL?
A: It is a Reduced Pressure Zone (RPZ) backflow preventer, designed for maximum protection against both back-siphonage and backpressure.

Q: What are key features of this model?
A: It includes a lead-free bronze body, wye-pattern design for compact installation, dual check valves, and a relief valve for safe pressure discharge.

Q: Why is the RPZ design important?
A: It provides the highest level of backflow protection by discharging water when unsafe pressure conditions occur, ensuring drinking water safety.

Q: Where is it commonly installed?
A: Used in irrigation systems with chemical exposure risk, commercial buildings, and other high-risk potable water applications.

Q: Does it require maintenance?
A: Yes, it requires periodic certified testing and inspection to ensure proper operation and compliance with plumbing codes.


Maintenance Tips
  • Inspect regularly for leaks, corrosion, and relief valve discharge activity.
  • Test annually by a certified tester to ensure proper reduced pressure backflow prevention and code compliance.
  • Flush the assembly periodically to reduce sediment buildup in check valves and relief components.
  • Clean strainers and internal parts to maintain consistent flow and reliable operation.
  • Replace worn seals, O-rings, or check modules with approved repair kits as needed.
  • Maintain clear access for inspection, testing, and servicing, and protect from freezing conditions.