Skip to product information
1 of 10

Zurn

Zurn Wilkins 950XLT2 3/4" Lead-Free Double Check Valve with Top Access - 34-950XLT2

Zurn Wilkins 950XLT2 3/4" Lead-Free Double Check Valve with Top Access - 34-950XLT2

review stars 1 Review

25% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $486.99 Sale price $365.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$22.99

$70.00

$52.99

Add-Ons Bundle

$30.00

$22.99

$70.00

$52.99

Bundle Offer

$100.00

$75.98

Recently Viewed

Zurn  Wilkins 950XLT2 3/4" Lead-Free Double Check Valve with Top Access - 34-950XLT2

The Zurn Wilkins 950XLT2 (SKU 34-950XLT2) is a 3/4" lead-free Double Check Valve Assembly engineered for dependable backflow protection in low-hazard potable water systems. Its compact footprint fits standard meter boxes and the top-access check covers allow service without removing the assembly from the line, reducing downtime and labor.

Approved by the Foundation for Cross-Connection Control and Hydraulic Research at USC, the 950XLT2 is suitable for below-grade installation in standard valve boxes and is commonly used in irrigation and commercial potable applications. Specification sheets, repair parts lists, and installation instructions are available in the product resources to assist with ordering, installation, and maintenance.

Features
  • Top-access check covers for quick maintenance and easier parts replacement.
  • Lead-free construction compliant with potable water regulations.
  • Corrosion-resistant stainless steel springs, fasteners, and ball valve handles for extended service life.
  • Replaceable seats and silicone seal rings reduce long-term maintenance costs.
  • Rated to 175 psi working pressure and 350 psi hydrostatic test pressure; maximum working temperature 180°F.
  • Protects against backsiphonage and backpressure; includes test cock plug to prevent fouling.
What our Experts Think
  • Reliable low-hazard backflow protection: The Zurn Wilkins 950XLT2 3/4" Double Check Valve Assembly (34-950XLT2) is designed to prevent backsiphonage and backpressure in non-health-hazard potable water systems, such as irrigation and fire sprinkler loops.
  • Top-access design for faster servicing: Built with top-access check covers, allowing internal maintenance without removing the full assembly from the line—reducing downtime and labor costs.
  • Compact, meter-box friendly layout: Engineered to fit standard valve boxes and tight installations, making it ideal for residential and light commercial irrigation setups.
  • Durable, corrosion-resistant construction: Features stainless steel springs, fasteners, and handles for long-term reliability in outdoor and buried applications.
  • Code-compliant and certified: Meets major standards including ASSE 1015, CSA, cUPC, and AWWA C510, ensuring compliance across most North American plumbing codes.
  • Designed for dependable system performance: Rated for up to 175 PSI working pressure and 180°F operating temperature, making it suitable for most municipal and irrigation supply conditions.
  • Professional-grade maintenance advantage: The replaceable internal seats and seals help extend service life and reduce long-term replacement costs compared to fully non-serviceable assemblies.

Q&A

Q: What is the Zurn Wilkins 34-950XLT2 3/4" Double Check Valve Assembly with Top Access?
A: The Zurn Wilkins 34-950XLT2 is a 3/4-inch lead-free double check valve assembly designed to prevent backflow contamination in low-hazard potable water systems by protecting against backsiphonage and backpressure.

Q: What applications is the 950XLT2 used for?
A: It is commonly used in irrigation systems, commercial plumbing, and other non-health-hazard water lines where reliable backflow protection is required.

Q: What are the key features of the 34-950XLT2?
A: It includes a top-access design for fast maintenance without removing the unit, corrosion-resistant internal components, and replaceable seals and seats to reduce long-term service costs.

Q: What are its performance ratings?
A: The valve typically supports up to 175 PSI working pressure and 180°F maximum temperature, with hydrostatic test pressure up to 350 PSI.

Q: Is the Zurn Wilkins 950XLT2 certified for potable water use?
A: Yes. It is lead-free and compliant with major standards including ASSE 1015, NSF/ANSI 61, CSA, and AWWA requirements.


Maintenance Tips
  • Perform annual testing by a certified backflow tester to ensure proper backflow prevention and compliance.
  • Inspect regularly for external leaks, corrosion, or valve chatter, especially after pressure fluctuations.
  • Keep shutoff valves and test cocks clean and operable, and check for debris buildup.
  • Flush the system periodically to reduce sediment accumulation inside the assembly.
  • Protect from freezing conditions with insulation or seasonal drainage where required.
  • Use only genuine repair parts from Zurn Wilkins to maintain certification and performance.
  • After any service, re-test the assembly before returning it to service.